53 research outputs found

    The sense of music education in education conceived as an engine of the knowledge economy: a philosophical framework proposal

    Get PDF
    Changes produced by the Knowledge-based Society and Economy have an influence on educational policies, attaching less importance to arts and music education within the curriculum. This article offers a literature review on present music education, where two opposite perspectives were found in: economic and social. The latter educational perspective aims the development of multiple human aspects in order to participate in current society. Music contributes to this goal, generating knowledge and action by means of it. To achieve this, philosophical thinking on music education, able to give fundament to music education and to respond to relevant topics for current education, should be elaborated

    Portable Electronic Tongue Based on Microsensors for the Analysis of Cava Wines

    Get PDF
    Cava is a quality sparkling wine produced in Spain. As a product with a designation of origin, Cava wine has to meet certain quality requirements throughout its production process; therefore, the analysis of several parameters is of great interest. In this work, a portable electronic tongue for the analysis of Cava wine is described. The system is comprised of compact and low-power-consumption electronic equipment and an array of microsensors formed by six ion-selective field effect transistors sensitive to pH, Na+, K+, Ca2+, Cl−, and CO32−, one conductivity sensor, one redox potential sensor, and two amperometric gold microelectrodes. This system, combined with chemometric tools, has been applied to the analysis of 78 Cava wine samples. Results demonstrate that the electronic tongue is able to classify the samples according to the aging time, with a percentage of correct prediction between 80% and 96%, by using linear discriminant analysis, as well as to quantify the total acidity, pH, volumetric alcoholic degree, potassium, conductivity, glycerol, and methanol parameters, with mean relative errors between 2.3% and 6.0%, by using partial least squares regressions.We acknowledge funding from the Spanish R & D National Program (MINECO, Projects TEC2011-29045-C04-01 and TEC2014-54449-C3-1-R). P.G.-G. is grateful to MINECO, Spain, for the financial support through a research studentship of the FPI Program. We acknowledge support by the CSIC Open Access Publication Initiative through its Unit of Information Resources for Research (URICI)

    Compact analytical flow system for the simultaneous determination of L-lactic and L-malic in red wines

    Get PDF
    During the malolactic fermentation of red wines, L-malic acid is mainly converted to L-lactic acid. Both acids should be precisely measured during the entire process to guarantee the quality of the final wine, thus making real-time monitoring approaches of great importance in the winemaking industry. Traditional analytical methods based on laboratory procedures are currently applied and cannot be deployed on-site. In this work, we report on the design and development of a bi-parametric compact analytical flow system integrating two electrochemical biosensors that could be potentially applied in this scenario. The developed flow-system will allow for the first time the simultaneous measurement of both acids in real scenarios at the real-time and in remote way. Miniaturized thin-film platinum four-electrode chips are fabricated on silicon substrates by standard photolithographic techniques and further implemented in a polymeric fluidic structure. This includes a 15 ”L flow cell together with the required fluidic channels for sample and reagent fluid management. The four-electrode chip includes counter and pseudo-reference electrodes together with two working electrodes. These are sequentially modified with electropolymerized polypyrrole membranes that entrap the specific receptors for selectively detecting both target analytes. The analytical performance of both biosensors is studied by chronoamperometry, showing a linear range from 5 × 10−6 to 1 × 10−4 M (LOD of 3.2 ± 0.3 × 10−6 M) and from 1 × 10−7 to 1 × 10−6 M (LOD of 6.7 ± 0.2 × 10−8 M) for the L-lactate and the L-malate, respectively. Both biosensors show long-term stability, retaining more than the 90% of their initial sensitivity after more than 30 days, this being a prerequisite for monitoring the whole process of the malolactic fermentation of the red wines (time between 20 and 40 days). The flow system performance is assessed with several wine samples collected during the malolactic fermentation process of three red wines, showing an excellent agreement with the results obtained with the standard method.info:eu-repo/semantics/publishedVersio

    Application of an E-Tongue to the Analysis of Monovarietal and Blends of White Wines

    Get PDF
    This work presents a multiparametric system capable of characterizing and classifying white wines according to the grape variety and geographical origin. Besides, it quantifies specific parameters of interest for quality control in wine. The system, known as a hybrid electronic tongue, consists of an array of electrochemical microsensors-six ISFET based sensors, a conductivity sensor, a redox potential sensor and two amperometric electrodes, a gold microelectrode and a microelectrode for sensing electrochemical oxygen demand-and a miniaturized optofluidic system. The test sample set comprised eighteen Catalan monovarietal white wines from four different grape varieties, two Croatian monovarietal white wines and seven bi- and trivarietal mixtures prepared from the Catalan varieties. Different chemometric tools were used to characterize (i.e., Principal Component Analysis), classify (i.e., Soft Independent Modeling Class Analogy) and quantify (i.e., Partial-Least Squares) some parameters of interest. The results demonstrate the usefulness of the multisensor system for analysis of wine

    Hybrid Electronic Tongues Applied to the Quality Control of Wines

    Get PDF
    The legislation of food industry is becoming increasingly strict with regard to the quality of food products. Therefore, the market is demanding for automatic systems of analysis that allow fast and accurate monitoring of the evolution of quality parameters in agrofood products or permit obtaining information to optimize production processes. In this context, sensors and more specifically microsensors play an important role since they allow fast and reproducible measurement of a large number of quality parameters with good reliability and can be implemented in portable systems. This paper presents a review of the results obtained with an electronic tongue based on different kinds of microsensors applied to wine analysis by the team of IMB-CNM. This multisensor system allows on one hand classifying the wine according to its features like grape variety, geographic origin, year, and organoleptic characteristics and on the other hand quantifying some parameters of interest in quality control, such as alcoholic degree, pH, ions, total acidity, glycerol, and color

    Reconfigurable multiplexed point of Care System for monitoring type 1 diabetes patients

    Get PDF
    At the point of care (POC), on-side clinical testing allows fast biomarkers determination even in resource-limited environments. Current POC systems rely on tests selective to a single analyte or complex multiplexed systems with important portability and performance limitations. Hence, there is a need for handheld POC devices enabling the detection of multiple analytes with accuracy and simplicity. Here we present a reconfigurable smartphone-interfaced electrochemical Lab-on-a-Chip (LoC)with two working electrodes for dual analyte determination enabling biomarkers' selection in situ and on-demand. Biomarkers selection was achieved by the use of electrodepositable alginate hydrogels. Alginate membranes containing either glucose oxidase (GOx)or lactate oxidase (LOx)were selectively electrodeposited on the surface of each working electrode in around 4 min, completing sample measurement in less than 1 min. Glucose and lactate determination was performed simultaneously and without cross-talk in buffer, fetal bovine serum (FBS)and whole blood samples, the latter being possible by the size-exclusion filtration capacity of the hydrogels. At optimal conditions, glucose and lactate were determined in a wide linear range (0–12 mM and 0–5 mM, respectively)and with high sensitivities (0.24 and 0.54 ÎŒA cm −2 mM −1 , respectively), which allowed monitoring of Type-1 diabetic patients with a simple dual analysis system. After the measurement, membranes were removed by disaggregation with the calcium-chelator phosphate buffer. At this point, new membranes could be electrodeposited, this time being selective to the same or another analyte. This conferred the system with on-demand biomarkers’ selection capacity. The versatility and flexibility of the current architecture is expected to impact in POC analysis in applications ranging from homecare to sanitary emergencies.Peer reviewe

    Ultramicroelectrode Array Based Sensors: A Promising Analytical Tool for Environmental Monitoring

    Get PDF
    The particular analytical performance of ultramicroelectrode arrays (UMEAs) has attracted a high interest by the research community and has led to the development of a variety of electroanalytical applications. UMEA-based approaches have demonstrated to be powerful, simple, rapid and cost-effective analytical tools for environmental analysis compared to available conventional electrodes and standardised analytical techniques. An overview of the fabrication processes of UMEAs, their characterization and applications carried out by the Spanish scientific community is presented. A brief explanation of theoretical aspects that highlight their electrochemical behavior is also given. Finally, the applications of this transducer platform in the environmental field are discussed

    Sustainable Production in the Food Industry Volume 6: Sustainable Primary Production (6): 128-149 (2021)

    Get PDF
    22 PĂĄginas.-- 2 FigurasChallenges in the food industry relate not only to demographic pressure and environment protection, but also to new consumer demands and specific health requirements. Multidisciplinary studies on raw materials, waste valorisation, efficient green technologies, new products and biodegradable smart packaging are needed. Real-time process control, quality, safety and authenticity will rely on powerful proces analytical technology, multi-sensors and advanced computing and digitalisation systemsPeer reviewe

    Sentidos del futuro: Lenguas electrĂłnicas

    Get PDF
    10 diapositivas.-- Trabajo de divulgaciĂłn presentado al 25Âș Aniversario de la creaciĂłn del CNM (1985-2010).Peer reviewe

    Hybrid technologies combining solid-state sensors and paper/fabric fluidics for wearable analytical devices

    No full text
    The development of diagnostic tools for measuring a wide spectrum of target analytes, from biomarkers to other biochemical parameters in biological fluids, has experienced a significant growth in the last decades, with a good number of such tools entering the market. Recently, a clear focus has been put on miniaturized wearable devices, which offer powerful capabilities for real-time and continuous analysis of biofluids, mainly sweat, and can be used in athletics, consumer wellness, military, and healthcare applications. Sweat is an attractive biofluid in which different biomarkers could be noninvasively measured to provide rapid information about the physical state of an individual. Wearable devices reported so far often provide discrete (single) measurements of the target analytes, most of them in the form of a yes/no qualitative response. However, quantitative biomarker analysis over certain periods of time is highly demanded for many applications such as the practice of sports or the precise control of the patient status in hospital settings. For this, a feasible combination of fluidic elements and sensor architectures has been sought. In this regard, this paper shows a concise overview of analytical tools based on the use of capillary-driven fluidics taking place on paper or fabric devices integrated with solid-state sensors fabricated by thick film technologies. The main advantages and limitations of the current technologies are pointed out together with the progress towards the development of functional devices. Those approaches reported in the last decade are examined in detail.Peer reviewe
    • 

    corecore